BlueStar PRZIDCB30V2 사용자 매뉴얼

다운로드
페이지 26
                                   P/N 750301 Page   20 
 
All specifications are subject to change without prior notification 
AIR SHUTTER ADJUSTMENTS 
Air shutter adjustments are preset at the fac-
tory.  These adjustments may need to be re-
done and/or fine tuned by the installer.  
These adjustments are normal.  They are 
the responsibility of the qualified installer 
and are not covered by your warranty

 
Before attempting to adjust any  burner air 
shutter, ensure the following has been 
checked and is correct: 
Proper gas type - match serial plate 
Proper regulator setting 
Orifice aligned - parallel with the venturi 
to the burner 
 
After verifying the gas, regulator and orifices 
adjust the air shutter by: 
Remove all top cooking sections associ-
ated with the burner(s) to be adjusted. 
Use a screwdriver to loosen the air shutter 
tightening screw. 
Turn the air shutter as required to adjust 
the flame - open gap for ―lazy‖ flame, 
close gap for ―lifting‖ flame. 
Test burner. 
If necessary, turn off burner and readjust. 
Turn off burner, tighten shutter screw and 
replace top sections when complete. 
A properly adjusted burner will have a coni-
cal shaped blue flame, however, on some lar-
ger burners (18K) the cones are close together 
and blend into one another.  Yellow tips nor-
mally flicker occasionally with natural gas, 
more often with propane.  The flame should 
be almost all blue all the time. 
 
CARE AND MAINTENANCE 
 
Please Note: 
Opening the air shutter gap will eliminate the yel-
low tipping on the burner. Closing the air shutter 
gap will prevent a noisy flame that lifts off the 
burner port.