Electric Dryer
PRODUCT MODEL NUMBERS
Installation spacing for recessed area or closet installation
The dimensions shown below are the recommended spacing for this dryer.
 
Additional spacing should be considered for ease of installation and servicing.
 
Additional clearances might be required for wall, door, floor moldings, and dryer venting.
 
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise 
transfer.
 
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door 
are required. Louvered doors with equivalent ventilation openings are acceptable. 
 
Companion appliance spacing should also be considered.
W10115226C
02/2012
MEDX500X, MEDX550X, MEDX600X, 
MEDX700A, MEDX700X
43"
(1092 mm)
*29
1
/
2
"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
   
 
   
43"
(1092 mm)
27"
(687 mm)
*29
1
/
2
"
(749 mm)
13¾"
(349  mm)
B
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
27"
(686 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
 
  29
¼"
(743 mm)
   
5
½"*
 (140 mm)
  48 in.
  
(310 cm )
2
*
2
  
24 in.
(155 cm )
*
2
       
3"*
(76 mm)
       
3"*
(76 mm)
A. Large opening side-swing door
B. Wide opening hamper door
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
 
Dryer Dimensions
*Most installations require a minimum 5½" (140 mm) 
clearance behind the dryer for the exhaust vent with 
elbow. See “Venting Requirements.”
Minimum spacing for recessed area or closet installation