30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the 
frame grounding conductor to the neutral wire of the 
copper power supply cord (see Figure 4):
1.  Remove the 3 screws at the lower end of the rear 
wire cover, then raise the lower end of the rear 
wire cover (access cover) upward to expose range 
terminal connection block (see figure 2).
2.  Remove the grounding strap from the terminal block 
and from the appliance frame.
3.  Using the nuts supplied with the literature package, 
connect the ground wire (green) of the copper 
power supply cord to the frame of the appliance 
with the ground screw, using the hole in the frame 
where the ground strap was removed (see Figure 4).
4.  Connect the neutral of the copper power supply 
cord to the center silver-colored terminal of the 
terminal block, and connect the other wires to the 
outer terminals. Match wires and terminals by color 
(red wires connected to the right terminal, black 
wires connected to the left terminal).
5.  Lower the terminal cover and replace the 3 screws.
Terminal Block
Silver Colored Terminal 
Red
Wire
Neutral 
(White Wire)
Ground (Bare 
Copper Wire)
To 240 V Receptacle
A User Supplied 
Strain-relief Must 
Be Installed at This 
Location
Black Wire
1 1/8" (2.9cm) 
Dia. Direct 
Connection 
Hole. Punch 
Out Knockout 
for 1 3/8" 
(3.5cm) Dia. 
Cord Kit Hole.
NOTE: Be sure to remove the 
supplied grounding strap.
Figure 4
4.
 Electrical Connection to the 
Range (U.S.A.)
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding 
conductor to the neutral wire of the copper power 
supply cord (see Figure 3):
1.  Remove the 3 screws at the lower end of the rear 
wire cover, then bend the lower end of the rear 
wire cover (access cover) upward to expose range 
terminal connection block (see Figure 2).
2.  Using the nuts supplied in the literature package, 
connect the neutral of the copper power supply cord 
to the center silver-colored terminal of the terminal 
block, and connect the other wires to the outer 
terminals. Match wires and terminals by color (red 
wires connected to the right terminal, black wires 
connected to the left terminal) (see figure 3).
3.  Lower the terminal cover and replace the 3 screws.
Figure 3
Silver Colored Terminal
1 1/8" (2.9 cm) Dia. 
Direct Connection 
Hole. Punch Out 
Knockout for 1 3/8" 
(3.5 cm) Dia. Cord 
Kit Hole.
To 240 V 
Receptacle
A User Supplied 
Strain-relief Must 
Be Installed at This 
Location.
Black 
Wire
Terminal
Block
Cord 
Mounting 
Plate
Neutral 
(White Wire)
Grounding
Strap
Red Wire