KitchenAid UXL6048YSS 사용 및 관리

다운로드
페이지 36
13
 
3. Use UL listed wire connectors and connect black wires (B) 
together.
4. Use UL listed wire connectors and connect white wires (A) 
together.
NOTE: When using an In-line blower motor system, the green (or 
green/yellow) ground wire in the conduit from the In-line blower 
motor system is to be connected with the green (or bare) wire of 
the home power supply cable and with the green/yellow wire (D) 
in the terminal box. 
5. Connect green (or bare) ground wire from home power supply 
to the green/yellow ground wire (D) in terminal box using UL 
listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
Complete Installation and Check 
Operation
1. Install grease filters. See the “Range Hood Care” section.
2. Check operation of the range hood blower and lights. See the 
“Range Hood Use” section.
3. If the range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
Disconnect power supply and check that the wiring is 
correct.
NOTE: To get the most efficient use from your new hood liner, 
read the “Range Hood Use” section.
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E. Home power supply
F. UL listed or CSA approved 
¹⁄₂
" (1.3 cm) strain relief
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A. Halogen lights
B. Halogen light switch
C. Blower control switches
D. Grease filter handle
E. Grease filter
C
A
A
A
A
B
D
E