Gas Dryer
PRODUCT MODEL NUMBERS
W10562336B
08/2013
NOTE: 
Most installations require a minimum 5" (102 mm) 
clearance behind the dryer for the exhaust vent with elbow.  
See “Venting Requirements”.
MGDB700B, MGDB725B, MGDB880B, MGDB980B
DRYER DIMENSIONS
Back view
Side view
Models with riser
Models without riser
Back view
Side view
Bottom view:
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with 
tested spacing of 0" (0 mm) clearance on sides and rear. 
 
Additional spacing should be considered for ease of 
installation and servicing.
 
Additional clearances might be required for wall, door, and 
floor moldings.
 
Additional spacing should be considered on all sides of 
the dryer to reduce noise transfer.
 
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilitation openings are 
acceptable.
 
Companion appliance spacing should also be considered.