GE GFDS170GH-WW 설치 설명서

다운로드
페이지 32
Installation Instructions
REQUIREMENTS FOR ALCOVE OR 
CLOSET INSTALLATION
MOBILE OR MANUFACTURED HOME 
INSTALLATION
3
- Explosion Hazard
WARNING
Keep flammable materials and vapors, such as gasoline, 
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a 
garage installation.
Failure to do so can result in death, explosion, or fire.
 
Installation must conform to the 
MANUFACTURED HOME CONSTRUCTION AND 
SAFETY STANDARD, TITLE 24, PART 32–80 or 
Standard CAN/CSA-Z240 MH, or, when such 
standard is not applicable, with AMERICAN 
NATIONAL STANDARD FOR MOBILE HOME,  
ANSI/NFPA NO. 501B.
 
The dryer MUST be vented to the outdoors. The 
exhaust vent must be securely fastened to a 
non-combustible portion of the mobile home.
 
The vent MUST NOT be terminated beneath a 
mobile or manufactured home.
 
The vent duct material MUST BE METAL.
 
KIT 14-D346-33 MUST be used to attach the dryer 
securely to the structure.
 
The vent MUST NOT be connected to any other 
duct, vent or chimney.
 
Do not use sheet metal screws or other 
fastening devices which extend into the interior 
of the exhaust vent.
 
Provide an opening with a free area of at least 
25 square inches for introduction of outside air 
into the dryer room.
 
See the sections for electrical connection 
information. 
 
If the dryer is approved for installation in an 
alcove or closet, it will be stated on a label on the 
dryer back.
 
The dryer MUST be vented to the outdoors. See 
the EXHAUSTING THE DRYER section.
 
Minimum clearance between dryer cabinet and 
adjacent walls or other surfaces is:
    0” 
either 
side
    3” 
front
    3” 
rear
 
Minimum vertical space from dryer to overhead 
shelves, cabinets, ceilings, etc., is 1” on top.
 
Consideration must be given to provide adequate 
clearance for installation and service.
 
Closet doors must be louvered or otherwise 
ventilated and have at least 60 square inches 
(387 square cm) of open area. If the closet 
contains both a washer and a dryer, doors must 
contain a minimum of 120 square inches (774 
square cm) of open area.
NOTE:  WHEN THE EXHAUST DUCT IS LOCATED IN 
THE REAR OF THE DRYER, THE CONFIGURATION OF 
THE DUCTING MAY REQUIRE GREATER THAN 3” OF 
REAR CLEARANCE.
Gas Dryers Only:
 
No other fuel burning appliance shall be installed 
in the same closet as a gas dryer.
 
The dryer must be disconnected from the gas 
supply piping during pressure testing at pressures 
greater than ½ psi (3.5 kPa).
 
A 1/8 inch NPT minimum plugged tapping, 
accessible for test gauge connection, must be 
installed immediately upstream of the gas supply 
connection to the dryer.
MINIMUM CLEARANCE OTHER THAN 
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and 
for air opening are: 0” both sides, 1” front and 
3” rear. Consideration must be given to provide 
adequate clearance for installation and service.