The PC board activates the water drain pump for 20 seconds, 
pumping out most of the water contained in the water reservoir.   
• 
The water can be pumped out up a rise of to 1.5m (59”) or   
 
 
 
 
 
 
 
 
 
 
   over a on horizontal length of 1.5m (59”).   
 
 
 
 
 
 
 
 
 
 
• 
If water level  switch 2 closes, transmitting a low-voltage 
current to the PC board, the PC board activates the buzzer 
alarm, informing you  that the drain pump, water level 
switch or drain tube may be malfunctioning. 
Schematic Diagram 
 
NOTE: 
The  outlet of the drain hose 
must be raised higher than the 
water surface  to prevent the 
drained water from flowing 
back into the water reservoir. 
WARNING! 
If alarm buzzer sounds, turn 
off the ice maker and the 
water supply, remove all ice 
from storage bin, and wipe up 
any water that may have 
overflowed. Check if there is 
any water in water trough at 
back of unit; if no water, 
drainage pump may not be 
receiving the proper amount 
of power. Check power 
source. If the problem can be 
corrected, turn on the unit 
again. Also check that none 
of the water lines are kinked. 
If the problem remains, 
contact SUMMIT Customer 
Service.