National Instruments 800 Series 사용자 설명서
Appendix C
LED Indicators
C-2
© National Instruments Corporation
LEDs and System Startup Cycle
Table C-1 shows a system startup cycle and possible points of failure,
up to and including the state in which the
up to and including the state in which the
VXIinit
initialization
program asserts the ONLINE LED.
Table C-1. LEDs and System Startup Status
Step
LEDs Lit
Status
Possible Problem if
VXIpc 800 Fails
1
None
Machine just turned on.
The VXIpc 800 is not receiving
power.
power.
2
FAILED,
SYSFAIL
SYSFAIL
Now asserting SYSFAIL because
VXIbus interface has not been
initialized yet.
VXIbus interface has not been
initialized yet.
Power-on self configuration (POSC)
cannot execute because of problems
with system reset or because the
POSCEN switch is incorrectly
configured.
cannot execute because of problems
with system reset or because the
POSCEN switch is incorrectly
configured.
3
FAILED,
TEST
TEST
VXI interface is being initialized by
MITE power-on self configuration
(POSC) circuitry.
MITE power-on self configuration
(POSC) circuitry.
POSC has stalled.
4
TEST
POSC circuitry has initialized VXI
interface, setting PASSED and
DONE bits.
interface, setting PASSED and
DONE bits.
POSC stalled before clearing the
TEST LED.
TEST LED.
5
None
POSC cycles are complete. VXI port
is ready to respond to Resource
Manager inquiries.
is ready to respond to Resource
Manager inquiries.
POSC completed successfully;
however, the Resource Manager
either hung or was not executed.
however, the Resource Manager
either hung or was not executed.
6
ONLINE
Resource Manager has been
executed, indicating that the VXI
software can now communicate with
the VXI circuitry.
executed, indicating that the VXI
software can now communicate with
the VXI circuitry.
Resource Manager interface
initialized successfully.
initialized successfully.