LEDs and System Startup Cycle
Table C-1 shows a system startup cycle and possible points of failure, 
up to and including the state in which the 
VXIinit
 initialization 
program asserts the ONLINE LED. 
Table C-1.  LEDs and System Startup Status
Step
LEDs Lit
Status
Possible Problem if 
VXIpc 800 Fails
1
None
Machine just turned on.
The VXIpc 800 is not receiving 
power.
2
FAILED,
SYSFAIL
Now asserting SYSFAIL because 
VXIbus interface has not been 
initialized yet.
Power-on self configuration (POSC) 
cannot execute because of problems 
with system reset or because the 
POSCEN switch is incorrectly 
configured.
3
FAILED,
TEST
VXI interface is being initialized by 
MITE power-on self configuration 
(POSC) circuitry.
POSC has stalled.
4
TEST
POSC circuitry has initialized VXI 
interface, setting PASSED and 
DONE bits.
POSC stalled before clearing the 
TEST LED.
5
None
POSC cycles are complete. VXI port 
is ready to respond to Resource 
Manager inquiries.
POSC completed successfully; 
however, the Resource Manager 
either hung or was not executed.
6
ONLINE
Resource Manager has been 
executed, indicating that the VXI 
software can now communicate with 
the VXI circuitry.
Resource Manager interface 
initialized successfully.