Desa EFS33NRA 사용자 설명서

다운로드
페이지 36
www.desatech.com
107172-01K
19
OPERATING FIREPLACE
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not 
use any phone in your building.
•  Immediately  call  your  gas  supplier 
from a neighborʼs phone. Follow the 
gas supplierʼs instructions.
•  If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, donʼt 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
INSTRUCTIONS
 WARNING: You must operate 
this fireplace with the fireplace 
screen in place. Make sure fire-
place screen is installed before 
running fireplace. 
NOTICE: During initial operation 
of new heater, burning logs will 
give off a paper-burning smell. 
Orange flame will also be pres-
ent. Open damper or window to 
vent smell. This will only last a 
few hours. 
1.  STOP!  Read  the  safety  information, 
column 1.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Set selector switch in OFF position.
  WARNING:  Burners  will 
come  on  automatically  within 
one  minute  when  the  selector 
switch is in the ON position after 
the pilot is lit. 
4.  Press in and turn control knob clockwise 
 to the OFF position.
5.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information, column 1. If you donʼt 
smell gas, go to the next step.
6.  Press in and turn control knob counter-
clockwise 
 to the PILOT position. 
Press in control knob for five (5) seconds 
(see Figure 32). 
 
Note:
 You may be running this heater for 
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be 
pressed in for 30 seconds or more. This will 
allow air to bleed from the gas system.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
O
F
F
   
PIL
OT   
LO
 
IH
 
AUTO
OFF
ON
O
N
    
    
     
   
Figure 32 - Control Knob and Ignitor 
Button Location (Shown as Supplied, No 
Control Options)
Control Knob
Ignitor Button
 Selector Switch
Flame Adjustment 
Knob