1.  This appliance is only for use with the type of 
gas indicated on the rating plate. This appliance 
is not convertible for use with other gases. 
2.  Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply 
tank(s) outdoors (propane/LP units only).
3.  If you smell gas
•  shut off gas supply
•  do not try to light any appliance
•  do not touch any electrical switch; do not 
use any phone in your building
•  immediately call your gas supplier from 
a  neighborʼs  phone.  Follow  the  gas 
supplierʼs instructions
•  if you cannot reach your gas supplier, call 
the fire department
4.  This fireplace shall not be installed in a bed-
room or bathroom.
5.  Do not use this fireplace as a wood-burning 
fireplace. Use only the logs provided with the 
fireplace. 
6.  Do not add extra logs or ornaments such as 
pine cones, vermiculite or rock wool. Using 
these added items can cause sooting. Do not 
add lava rock around base. Rock and debris 
could fall into the control area of fireplace.
7.  To prevent the creation of soot, follow the 
instructions in Cleaning and Maintenance
page 23.
8.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
9.  This fireplace needs fresh air ventilation to run 
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS shuts down the fireplace if enough fresh 
air is not available. See Air for Combustion 
and  Ventilation,  page  6.  If  fireplace  keeps 
shutting off, see Troubleshooting, page 25.
10.  Do not run fireplace
•  where  flammable  liquids  or  vapors  are 
used or stored
•  under dusty conditions
11.  Do not use this fireplace to cook food or burn 
paper or other objects.
12.  Do not use fireplace if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the fireplace and to 
replace any part of the control system and any 
gas control which has been under water. 
SAFETY INFORMATION
Continued
13.  Do not operate fireplace if any log is broken. 
Do not operate fireplace if a log is chipped 
(dime-sized or larger). 
14.  Turn fireplace off and let cool before servicing. 
Only a qualified service person should service 
and repair fireplace.
15.  Operating fireplace above elevations of 4,500 
feet could cause pilot outage. 
16.  To prevent performance problems in propane/LP 
units, do not use propane/LP fuel tanks of less 
than 100 lbs. capacity (propane/LP units only).
17.  Provide adequate clearances around air openings.
PRODUCT IDENTIFICATION
Optional Blower 
Assembly
(Not Included)
Optional 
Remote 
Control
Top Louver 
Assembly 
Fireplace 
Hood 
Bottom Louver Assembly 
Screen 
Assembly 
Top Outer 
Casing 
Firebox 
Support 
Figure 2 - Fireplace (VSGF33NRA Shown)
Figure 1 - Log Base Assembly 
(VSGF33NRA Shown)
Front 
Log 
Rear Log
Middle Log
Base Assembly
Front 
Burner
Piezo 
Ignitor
Rear Burner