DCT3080 Installation Manual 
 
32 
Boot Cycle 
After connecting the proper cabling to the DCT3080, plug the power 
cord into the DCT3080 and electrical wall outlet. Begin performing the 
boot cycle procedure: 
ƒ
  After a few moments, the LED displays HUNT and then FR 1.  
ƒ
  The DCT3080 searches for the headend out-of-band (OOB) 
frequency carrier. If the OOB frequency is not set to 75.25 MHz, the 
LED flashes FR 1 and then flashes FR 2. This searching process 
repeats until the correct OOB frequency is found and the required 
message for the DCT3080 model is acquired.  
ƒ
  The LED displays and OOB frequencies are: 
Table 2-4  
LED displays and OOB frequencies 
Display Frequency Description 
dl 
N/A 
OOB network download in progress  
EF 
N/A 
Erasing Flash memory 
FP 
N/A 
Flash memory is being programmed 
____ 
N/A 
Network download complete 
Hunt 
N/A 
Hunting for OOB frequency 
FR 1 
75.25 
MHz 
Attempting to lock on frequency 1 
FR 2 
104.20 
MHz 
Attempting to lock on frequency 2 
FR 3 
72.75 
MHz 
Attempting to lock on frequency 3 
FR 4 
92.25 
MHz 
Attempting to lock on frequency 4 
FR 5 
98.25 
MHz 
Attempting to lock on frequency 5 
FR 6 
103.75 
MHz 
Attempting to lock on frequency 6