SECTION 5—CENTER MOUNT FOOTRESTS
20
Chairs built after 12/01/2008
WARNING
While the wheelchair is moving, minimum ground clearance for the front rigging is
three inches. If the wheelchair is not moving, the front rigging MUST maintain a
minimum of one inch ground clearance - otherwise personal injury and damage may
result.
three inches. If the wheelchair is not moving, the front rigging MUST maintain a
minimum of one inch ground clearance - otherwise personal injury and damage may
result.
NOTE: For this procedure, refer to FIGURE 5.3.
1. Remove the two mounting screws that secure the button head cleat to the extension
housing.
2. Adjust the footrest extension tube to the desired height.
3. Secure the extension tube to the desired height with the button head cleat and
mounting screws. Securely tighten.
4. Repeat STEPS 1‐3 for the other extension tube.
FIGURE 5.3 Adjusting the Height of the Manual Center Mount Footrest -
Extension
Housing
Extension Tube
Mounting Screws
Extension Tube Mounting Holes
Button Head Cleat