DELL H200 사용자 설명서

다운로드
페이지 92
PERC H200 and 6Gbps SAS HBA BIOS
51
Exit Screen
It is important to exit the SAS BIOS Configuration Utility properly, 
because some changes take effect only when you exit. From the Adapter List, 
press <Esc> to exit. In addition, a similar exit screen appears when you 
exit most other screens, and it can be used to save settings.
Performing Configuration Tasks
The following configuration tasks can be performed using a PERC H200 card:
Creating a RAID 0, RAID 1, or RAID 10 virtual disk
Viewing virtual disk properties
Activating a virtual disk
Migrating and Activating a virtual disk
Hot Spare failover
Replacing and Rebuilding a degraded virtual disk
Assigning a Preferred Boot Device
Consistency 
Check
This option is used to run a consistency check on a 
redundant RAID volume.
This option is grayed out under the following conditions:
• The volume is RAID 0
• The volume is not optimal
• The volume has a consistency check pending
• The volume is already running a consistency check
Activate 
Volume
This option is used to activate an inactive (foreign) volume. The option 
is grayed out if there are no inactive arrays.
Delete 
Volume
This option is used to delete the currently displayed volume.
Table 6-3.
Manage Volume Field Descriptions (continued)
Field
Description
PERC H200.book  Page 51  Tuesday, July 13, 2010  4:15 PM