Zebra Technologies P1071336-002 사용자 설명서

다운로드
페이지 70
59
WebLink Set/Get/Do Commands
weblink.ip.conn[1|2].test.location
1/20/15
P1071336-002 
Example • 
The test connection can assist the user in several ways/scenarios:
1.
If the 
test.test_on
 value is set to 
"failure"
, any time the main weblink 
(
conn[1|2].location
) connection fails to connect then the 
test.location
 URL will be 
used. In this situation, an attempt will be made to contact the remote URL in 
test.location
, using authentication and proxy configuration that is specified by the main 
connection.
2.
If the 
test.test_on
 value is set to 
"interval"
 an attempt will be made to contact the 
remote URL in 
test.location
 every 
test.retry_interval
 seconds, using authentication 
and proxy configuration that is specified by the main connection.
3.
If the 
test.test_on
 value is set to 
"both"
, then scenario 1 and 2 will both occur. This is 
useful for users who will use an HTTP connection to move through their firewall - and 
thereafter frequently refresh the connection to indicate to their firewall that there is still 
activity for the purpose of keeping the connection alive.