FLOW CHART
ISPLAY COLOR SETUP (examples)
Example 1:
Output 1 & Output 2: SSR
Alarm setup: Absolute, Above, Alarm 2 HI Value 
"ALR.H" =200, Alarm 1 HI Value "ALR.H"=400
Color Display setup: Normal Color "N.CLR"=Green, Alarm 1
Color "1.CLR"=Amber, Alarm 2 Color "2.CLR"=Red
Display colors change sequences:
GREEN
|          RED
|         AMBER
•-➤----------------•-----------------------•--------------------------------➤
0              AL2.H=200          AL1.H=400        
Example 2:
Output 1: Relay, Set Point 1 = 200,
Output 2: Relay, Set Point 2 = 200
Alarm 1 setup: Deviation, Band, "ALR.H" = 20 
Alarm 2 setup: Deviation, Hi/Low, "ALR.H = 10", "ALR.L = 5"
Color Display setup: "N.CLR"=Green, "1.CLR"=Amber,
"2.CLR"=Red
Display colors change sequences:
AMBER |  RED |  GREEN |  GREEN RED AMBER
•-➤--------•----------•--------------•--------------•----------•------------➤
0          180      195            200          210       220 
READING CONFIGURATION SETUP
(operation example)
Below is a flowchart showing how to navigate through the
submenus of the Reading Configuration menu item by
pressing the front buttons.
Where:
CALC/VALUE = Calculated input based on
the transducer specification
[Without Known Loads (DSBL)]
ACT/VALUE = Actual signal being received
[Known Loads (ENBL)]
MQS3536/1204
SPECIFICATION
Accuracy:
0.03% rdg.
Resolution:
10 / 1 µV process
Linearization Points:
10 points
Temperature Stability:
50 ppm/°C process
Display:
4-digit, 9-segment LED, 
10.2 mm (0.40") with red, green and
amber programmable colors
Input Types:
Analog Voltage and Current
Voltage:
0 to 100 mV, 0 to 1 V (+100 mV),
0 to 10 Vdc
Input Impedance: 
10 MΩ for 100 mV
1 MΩ for 1 or 10 Vdc
Current:
0 to 20 mA(5 Ω load)
Output 1:
Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse, Analog Voltage and Current
Output 2:
Relay 250 Vac @ 3 AResistive Load,
SSR, Pulse
Options: Communication
RS-232 / RS-485 or
Excitation: 5 Vdc @ 40 mA, 
10 Vdc @ 60 mA
Exc. not available for Low Power Option
Line Voltage/Power:
90 - 240 Vac ±10%, 50 - 400 Hz*, 
or 110 - 375 Vdc, 4 W
* No CE compliance above 60 Hz
Low Voltage Power Option:
12 - 36 Vdc, 3 W**
** Units can be powered safely with 24 Vac
but No Certification for CE/UL are claimed.
Dimensions:
25.4 H x 48 W x 126.3 D mm 
(1.0 x 1.89 x 5")
Weight:
127 g (0.28 lb)
Approvals:
UL, C-UL, CE per EN61010-1:2001
d
d
b
b
• • •
d
d
b
d
b
b
d
d
b
b
• • •
d
b
d
d
d
d
bc
d
d
d
d
d
d
d
d
•    •    •    •    •    •    •    •
a
a
a
bc
bc
bc
bc
bc
WARRANTY/DISCLAIMER
OMEGAENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of
one (1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will
extend  the  warranty  period  for  four (4)  additional  years if  the  warranty  card  enclosed  with  each  instrument  is
returned to OMEGA.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will
issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply
to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit
shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions  outside  of  OMEGA’s  control.  Components  which  wear  are  not  warranted,  including  but  not  limited  to
contact points, fuses, and triacs.
OMEGA is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,  OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO
OTHER  WARRANTIES  OR  REPRESENTATIONS  OF  ANY KIND  WHATSOEVER,  EXPRESS  OR  IMPLIED,
EXCEPT  THAT  OF  TITLE,  AND  ALL IMPLIED  WARRANTIES  INCLUDING  ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with
respect  to  this  order,  whether  based  on  contract,  warranty,  negligence,  indemnification,  strict  liability  or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGA be liable for consequential, incidental or special damages.
CONDITIONS:    Equipment  sold  by  OMEGAis  not  intended  to  be  used,  nor  shall  it  be  used:  (1)  as  a  “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications
or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
used  on  humans,  or  misused  in  any  way,  OMEGAassumes  no  responsibility  as  set  forth  in  our  basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless
from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGACustomer  Service  Department.  BEFORE
RETURNING ANY PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST OBTAIN AN AUTHORIZED  RETURN  (AR)
NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE  DEPA RTMENT (IN  ORDER  TO AVOID  PROCESSING
DELAYS).  The  assigned AR  number  should  then  be  marked  on  the  outside  of  the  return  package  and  on  any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in
transit.  
FOR WARRANTY RETURNS, please have the
following information available BEFORE 
contacting OMEGA:
1.
Purchase Order number under which the product
was PURCHASED,
2.
Model and serial number of the product under
warranty, and
3.
Repair instructions and/or specific problems
relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1. 
Purchase Order number to cover the COST of the
repair,
2.
Model and serial number of product, and
3.
Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGAis a registered trademark of OMEGAENGINEERING, INC.
© Copyright 2004 OMEGAENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGAENGINEERING, INC.
PATENT AND TRADEMARK NOTICE: This product is covered by one or more of the following patents:  U.S. Pat.
No. Des. 336,895; 5,274,577; 6,243,021 / CANADA 2052599; 2052600 / ITALY 1249456; 1250938 / GERMANY DE
41 34398 C2 / SPAIN 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / FRANCE BREVET NO. 91
12756. The “Meter Bezel Design” is a trademark of Newport Electronics, Inc. USED UNDER LICENSE. Other U.S.
and International Patents pending or applied for.
This  device  is  marked  with  the  international  caution  symbol.      It  is  important  to  read  the
Setup Guide before installing or commissioning this device, as the guide contains important
information relating to safety and EMC.
WARNING: These  products  are  not  designed  for  use  in,  and  should  not  be  used  for,  patient-
connected applications.
It  is  the  policy  of  OMEGAto  comply  with  all  worldwide  safety  and  EMC/EMI  regulations  that  apply.
OEMGAis constantly pursuing certification of its products to the European New Approach Directives.
OMEGAwill add the CE mark to every appropriate device upon certification.
The  information  contained  in  this  document  is  believed  to  be  correct,  but  OMEGAEngineering, Inc.
accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
TRADEMARK NOTICE:
®
,
omega.com
®
,
and 
®
are  Trademarks  of
OMEGAENGINEERING, INC.
®
USA
MADE IN
CNiS32
Process / Strain Gauge
Controller
Servicing North America:
USA: 
 
         One Omega Drive, P.O. Box 4047
ISO 9001 Certified
 
         Stamford CT 06907-0047
 
 
         TEL: (203) 359-1660 
 
FAX: (203) 359-7700
 
 
         e-mail: info@omega.com
Canada:   
         976 Bergar
 
 
         Laval (Quebec) H7L 5A1
 
 
         TEL: (514) 856-6928 
 
FAX: (514) 856-6886
 
 
         e-mail: info@omega.ca
For immediate technical or application assistance:
USA and Canada:           Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
®
 
 
         Customer Service: 1-800-622-2378 / 1-800-622-BEST
®
 
 
         Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
®
Mexico and  
         TEL: (001)800-TC-OMEGA
®
 
FAX: (001) 203-359-7807 
Latin American: 
         En Español: (001) 203-359-7803 
 
 
         e-mail: espanol@omega.com
Servicing Europe:
Benelux:  
         Postbus 8034, 1180 LA Amstelveen, The Netherlands
 
 
         TEL: +31 20 3472121 
 
FAX: +31 20 6434643
 
 
         Toll Free in Benelux: 0800 0993344 
 
 
         e-mail: sales@omegaeng.nl
Czech Republic: 
         Frystatska 184, 733 01 Karviná
 
 
         TEL: +420 59 6311899   
FAX: +420 59 6311114
 
 
         e-mail: info@omegashop.cz
France:   
         11, rue Jacques Cartier, 78280 Guyancourt
 
 
         TEL: +33 1 61 37 29 00  FAX: +33 1 30 57 54 27
 
 
         Toll Free in France: 0800 466 342
 
 
         e-mail: sales@omega.fr
Germany/Austria:           Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
 
 
         TEL: +49 7056 9398-0   
FAX: +49 7056 9398-29
 
 
         Toll Free in Germany: 0800 639 7678
 
 
         e-mail: info@omega.de
United Kingdom:           One Omega Drive
ISO 9002 Certified
 
         River Bend Technology Centre
 
 
         Northbank, Irlam  Manchester M44 5BD United Kingdom  
 
 
         TEL: +44 161 777 6611  FAX: +44 161 777 6622
 
 
         Toll Free in England: 0800 488 488
 
 
         e-mail: sales@omega.co.uk
OMEGAnet
®
 On-Line Service
www.omega.com
Internet e-mail
info@omega.com
®
®