In the event of erratic operation of the transceiver, it is possible that data on the micropro-
cessor may have become corrupted. While this is a highly unusual situation, the only path
to recovery may involve resetting of the microprocessor. Here’s how to do this:
1.
Turn the radio off.
2.
Press and hold in the MONI switch (just below the PTT switch) while turning the
radio on.
3.
Rotate the DIAL knob to select one of the choices from the reset menu:
F1 SETRST
: Resets the Set (Menu) mode settings to their factory defaults.
F2 MEMRST
: Clears the Memory settings to factory defaults.
F3 MB RST
: Clears the Memory Bank Assignments.
F4 ALLRST
: Clears all memories and other settings to factory defaults.
4.
Press the [F] key momentarily to complete the reset procedure.
The “F5” option is used for setting up the “Memory Only” mode, and “F6”
is used for Cloning. See page 34 for details regarding the memory Only mode,
and the next section regarding Cloning.