Thermador PDR30 사용자 설명서
Thermador
Professional Ranges Models: PDR30/36/48…PRG30/36/48
The control continuously monitors system parameters for control and oven failures and reports a fault code
when a system problem is detected. The control utilizes the ovens blue “on light” and oven “heating light” to
report a detected fault code. The control will continue to flash the lights in the appropriate sequence as long as
the fault exists.
Detection of a fault does not hinder the ability of the control to continue to function if the fault is not critical for
the intended operation. For example: If the range door latch is inoperative, the range will continue to cook since
the fault would only prevent the range from self-cleaning.
ERROR CODE
LIGHT SEQUENCE CODE
DESCRIPTION
E1 22
EEPROM
ERROR
E2
01
CONTROL NOT CALIBRATED
E3 10
SENSOR
OPEN
E4 12
SENSOR
SHORTED
E5 21
POTENTIONMETER
FAILURE
E6 32
OVER
TEMPERATURE-COOKING
E7 23
OVER
TEMPERATURE-CLEANING
E9
43
NO COOLING FANS
E11
44
DOOR LATCH FAULT
E12
11
EXP. BOARD NOT CONNECTED
E13
13
VCC LIFT OFF ERROR
E14
55
SELECTOR SWITCH ERROR