5)   Remove damaged supply cord set by taking 
off the 4 electrical connection screws (block 
L1, N, L2 and Ground screw, see diagram) 
6)   Insert the new supply cord set in the strain 
relief and lock it with two strain relief's 
screws in suitable position. 
7)   Fix well the ring terminals G, L1, N, L2 of the 
new supply cord set as shown in diagram 
with its 4 screws 
8)   Re‐install the back enclosure panel with 6 
screws 
9)  Slide the appliance back into its proper 
location 
10) Re‐connect the appliance to the electrical 
power. 
 
 
ELECTRICAL GROUNDING 
This appliance is equipped with a four‐prong plug 
for your protection against shock hazard and 
should be plugged directly into a properly 
grounded receptacle. Do not cut or remove the 
grounding prong from this plug. 
 
 
WARNING! 
ELECTRICAL SHOCK HAZARD 
Disconnect electrical power at the circuit 
breaker box or fuse box before installing the 
appliance.  
Provide appropriate ground for the appliance. 
Use copper conductors only. 
Failure to follow these instructions could result 
in serious injury or death 
 
 
CAUTION 
Label all wires prior to disconnecting when 
servicing controls. Wiring errors can cause 
improper and dangerous operation. 
Verify proper operation after servicing 
 
LOCATION OF APPLIANCE PLATES 
The data rating plate shows the model and serial 
number of your range. It is located under the 
front edge of the range cooktop, and is visible 
when the oven door is open (see illustration) 
 
A= Rating plate(s) located under front edge of 
cooktop 
B= Wiring / schematic diagram placed on 
backside panel and on installation booklet