Error Messages
The following table details the cause and subsequent response of the appliance to errors. 
The alarm message will end when the alarm trigger is no longer present, except PF1 and PF2 that require the appliance to be turned Off, then On again.
Technical Specifications
Electrical Wiring
POLAR appliances are supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard. 
The plug is to be connected to a suitable mains socket. 
POLAR appliances are wired as follows:
 Live wire (coloured brown) to terminal marked L
 Neutral wire (coloured blue) to terminal marked N
 Earth wire (coloured green/yellow) to terminal marked E 
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Compliance
POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and 
federal authorities.
POLAR products have been approved to carry the following symbol: 
Error Message 
(flashing)
Cause
Appliance Response
Action
HtA
The inner temperature exceeds 
the set maximum temperature 
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or 
qualified Technician 
LtA
The inner temperature exceeds 
the set minimum temperature 
Display flashes
Alternating error message and current temperature
Check Troubleshooting Guide
If problem persists call POLAR agent or 
qualified Technician
PF1
Short circuit or interruption of 
the thermostat probe input line
Display flashes
Compressor operates as specified by 
parameter ‘=23’
PF2
Short circuit or interruption of 
the evaporator probe input line
Display flashes
Defrost as specified by parameters d8 and d9
HLA
Inner temperature greater than 
90°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
LLA
Inner temperature lower than 
-45°C
Display flashes
Alternating error message and current temperature
Call POLAR agent or qualified Technician
Model
Voltage
Power
Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight 
(Kg)
G596
230V 50Hz 
340W
1.5A
-2°C to 10°C
282
R134a 240g
850 x 1360 x 700
98
G597
230V 50Hz
340W
1.5A
-2°C to 10°C
417
R134a 240g
850 x 1795 x 700
134
G598
230V 50Hz
450W
2A
-2°C to 10°C
563
R134a 250g
850 x 2230 x 700
153
G599
230V 50Hz
1000W
4.35A
-10°C to -20°C
282
R404 300g
850 x 1360 x 700
103
G600
230V 50Hz
1000W
4.35A
-10°C to -20°C
417
R404 260g
850 x 1795 x 700
136
G601
230V 50Hz
1000W
4.35A
-10°C to -20°C
563
R404 320g
850 x 2230 x 700
155
G621
230V 50Hz
340W
1.5A
-2°C to 10°C
417
R134a 240g
900 x 900 x 700
140
G622
230V 50Hz
340W
1.5A
-2°C to 10°C
368
R134a 250g
850 x 1365 x 700
107
U636
230V 50Hz
250W
1A
-2°C to 10°C
240
R134a 165g
850 x 900 x 700
70
U637
230V 50Hz
250W
1A
-2°C to 10°C
240
R134a 165g
850 x 900 x 700
71
U638
230V 50Hz
250W
1A
-2°C to 10°C
240
R134a 165g
850 x 900 x 700
72