5. VENTILATION HEIGHTS
Refer to FIG 1., Page 2
Installation with roof
Minimum Ventilation
vent and lower side vent
heights  in:
REFRIGERATOR
INCHES
MM
RM2612
54
1372
RM2812
60
1524
LOWER VENT CUTOUT
UPPER VENT CUTOUT
5-1/2"
21-9/16"
13-3/4"
23-3/4"
NOTE:  All cutout dimensions are +/– 1/8".
6. CLEARANCES
Minimum clearances in inches to combustible materials are:
G:
Top
0"
K:
Side
0"
L:
Bottom
0"
M:
Rear
0"
N:
See NOTE
NOTE: Clearance "M" is between the rearmost part of the
refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bottom
of the lower vent to the roof material. For ventilation
height, refer to 
Section A. Installation, Item 5. Ventilation
Heights. See FIG. 2.
FIG. 2
FIG. 3
Refrigerator
Overall
Installation
Recess
Model
Dimensions
Dimensions
Dimensions
Height
Width
Depth
Height
Width
Depth
Height
Width
Depth
A
B
C
h
w
d
H
W
D
RM2612   (Inches)
51
22-23/32
24-9/16
49-7/32
21-17/32
23-19/32
49-17/32
21-13/16
24-3/32
(mm)
1295
577
624
1250
547
599
1258
544
612
RM2812 (Inches) 56-13/16
24-39/64
24-9/16
55-1/8
23-7/16
23-19/32
55-7/16
23-11/16
24-3/32
(mm)
1443
625
624
1400
595
599
1408
601
612