Jenn-Air W10379137A 사용자 설명서

다운로드
페이지 80
18
To Install Anti-tip Boards
1. Mark the stud locations on rear wall 80" to 90" (203 cm to 
229 cm) above floor.
2. Securely attach one or two 2" x 4" x 32" (5 cm x 10 cm x 
81 cm) boards to wall studs behind refrigerator. Use six 
#8 x 3" (7.6 cm) (or longer) wood screws. The wood screws 
must be screwed into the studs at least 1½" (3.8 cm). The 
board(s) must overlap the compressor cover. 
Connect the Water Supply
Read all directions before you begin.
IMPORTANT: If you turn the refrigerator on before the water line is 
connected, turn the ice maker OFF.
Connect to Water Line
Parts Needed:
Minimum 7 ft (2.13 m) flexible, codes approved water 
supply line
Style 1 - Shutoff Valve Connection
NOTE: If your water line connection does not look like Style 1, see 
“Style 2 - Copper Line Connection.”
1. Unplug refrigerator or disconnect power supply.
IMPORTANT: Before attaching the tubing to shutoff valve, flush 
the main water supply line to remove particles and air in the water 
line. Allow enough flow so that water becomes clear. Flushing the 
water line may help avoid filters and/or water valves from 
becoming clogged.
2. Connect the flexible, codes approved water supply line to the 
water shutoff valve by threading the provided nut onto the 
shutoff valve as shown.
NOTE: The shutoff valve shown is in the side cabinet as 
recommended. 
3. Place the end of the tubing into a bucket, and turn shutoff 
valve ON.
4. Check for leaks. Tighten any nuts or connections (including 
connections at the valve) that leak.
Style 2 - Copper Line Connection
NOTE: If there is a water supply line that meets the specifications 
in “Water Supply Requirements,” proceed to “Connecting to 
Refrigerator.” If not, use the following instructions to connect to 
the household cold water supply.
1. Unplug refrigerator or disconnect power.
2. Turn OFF main water supply. Turn ON nearest faucet long 
enough to clear line of water.
3. Locate a ½" to 1
¹⁄₄" (1.25 cm to 3.18 cm) vertical cold water 
pipe near the refrigerator.
IMPORTANT: 
Make sure it is a cold water pipe.
Horizontal pipe will work, but drill on the top side of the 
pipe, not the bottom. This will help keep water away from 
the drill and keep normal sediment from collecting in the 
valve.
4. Determine the length of copper tubing you need. Measure 
from the connection on the lower left rear of refrigerator to the 
water pipe. Add 7 ft (2.1 m) to allow for cleaning. Use 
¹⁄₄" 
(6.35 mm) O.D. (outside diameter) copper tubing. Be sure both 
ends of copper tubing are cut square. 
5. Using a cordless drill, drill a 
¹⁄₄" (6.35 mm) hole in the cold 
water pipe you have selected.
6. Fasten the shutoff valve to the cold water pipe with the pipe 
clamp. Be sure the outlet end is solidly in the 
¹⁄₄" (6.35 mm) 
drilled hole in the water pipe and that the washer is under the 
pipe clamp. Tighten the packing nut. Tighten the pipe clamp 
screws slowly and evenly so washer makes a watertight seal. 
Do not overtighten.
A. Center board 
¹⁄₄
" (6.35 mm) max. above refrigerator
B. Two 2" x 4" x 32" (5 cm x 10 cm x 81 cm) boards
C. Attach to studs with six #8 x 3" (7.6 cm) screws
D. Compressor cover
E. Distance from bottom of anti-tip board to floor
B
A
C
2" (5 cm)
D
¹⁄₄
" (6 mm)
max. 
84"
(213.4 cm)
E
A. Bulb
B. Nut
C. Water tubing
A. Cold water pipe
B. Pipe clamp
C. Copper tubing
D. Compression nut
E. Compression sleeve
F. Shutoff valve
G. Packing nut
A
B
C
A
B
C
D
E
F
G