Integrated Installation - Full Height Grille 
To install the grille panel to the refrigerator:
1. Slide the upper and lower slots in each bracket onto the 
mounting pins extending upward from the top of the 
refrigerator. 
2. Push the grille panel forward to fully engage the spring clips 
and fasten the grille panel. 
To remove the grille panel from the refrigerator:
1. Open the door(s). 
2. Place both hands under the grille panel, grasping the bottom 
edge between your fingers and thumbs. 
3. Pull the grille panel straight out until the grille stops. Then, lift 
up on the grille panel to remove.   
Power On or Off Switch
1. Remove the top grille panel.
2. Press power switch to the On or Off position.
3. Replace the top grille panel.
IMPORTANT: Be sure the power switch is set to the On position 
after cleaning refrigerator or changing light bulbs.
Water Supply Requirements
Read all directions before you begin.
IMPORTANT:
When your refrigerator was installed, the water connection 
from the water source should have been connected to your 
refrigerator. If your refrigerator is not connected to a water 
source, see “Connect to Water Line” in the Installation 
Instructions. If you have any questions about your water 
connection, see “Troubleshooting” or call a licensed, qualified 
plumber.
If you turn the refrigerator on before the water line is 
connected, turn the ice maker OFF. See “Ice Maker and 
Storage Bin.”
All installations must meet local plumbing code requirements.
Water Pressure
A cold water supply with water pressure between 30 and 120 psi 
(207 and 827 kPa) is required to operate the water dispenser and 
ice maker. If you have questions about your water pressure, see 
“Troubleshooting” or call a licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
refrigerator needs to be between 30 and 120 psi (207 and 
827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 psi (276 kPa).
If the water pressure to the reverse osmosis system is less than 
40 psi (276 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If your refrigerator has a water filter, it may further reduce the 
water pressure when used in conjunction with a reverse 
osmosis system. Remove the water filter. See “Water Filtration 
System.”
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Water System Preparation
Please read before using the water system.
Immediately after installation, follow the steps below to make sure 
that the water system is properly cleaned.
1. Turn off the ice maker. Slide the ice maker On/Off control, 
located on the left-hand side of the ice bin, to the OFF (down) 
position as shown. 
NOTE: If your model has a base grille water filter, make sure the 
water filter is properly installed so that the Eject button is out. See 
“Water Filtration System.” 
2. Turn on the ice maker. Slide the ice maker On/Off control, 
located on the left-hand side of the ice bin, to the ON (up) 
position. Please refer to “Ice Maker and Storage Bin” for 
further instructions on the operation of your ice maker.
Allow 24 hours to produce the first batch of ice. 
Discard the first three batches of ice produced. 
A. Power switch
A
A. On/Off control
A
Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or 