Honeywell W8150 사용자 설명서

다운로드
페이지 12
Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL
3
68-0282—07
W8150 QUICK GUIDE
 No.
Name
Description
Function
1
G
F
Equipment fan
Allows W8150 to pass thermostat calls and, when necessary, turn on 
system fan for ventilation. This should be the only connection to G on the 
HVAC equipment.
2
R
C
24 Vac cooling system 
power
Provides power to G
F
 terminal to operate system fan, when necessary.
3
C
C
24 Vac cooling system 
common
Allows W8150 to monitor when system fan is energized.
4
C
H
24 Vac heating system 
common
Allows W8150 to monitor thermostat heat calls when W is energized.
5
W
Heating
Allows W8150 to monitor when heating is energized.
6
G
T
Thermostat (or other 
control) fan terminal
Allows W8150 to monitor when G
T
 is energized. All external equipment that 
controls the system fan should be wired to this terminal.
7
Switch
On (optimal ventilation)
Override
Off (Remote Only)
On (optimal ventilation) – W8150 ventilates, based on control settings.
Override – W8150 runs ventilation continuously.
Off (Remote Only) – W8150 supplies ventilation only when there is a 
remote call.
8
Light
Green
Indicates device is powered and operating normally. Used in Test Mode to 
signal if dial settings meet chosen standard.
9
Light
Red
Indicates the device is not operating normally. Used in Test Mode to signal 
if dial settings do not meet chosen standard.
10
DIP1
Ventilation limit
Choose between 60% (default) and 100% maximum fan run time allowed 
by W8150 for ventilation.
11
DIP2
Ventilation standard
Choose between ASHRAE 62.2 (default) and 62-1999 ventilation 
standards.
12
BEDROOMS 
Number of bedrooms
Used to calculate amount of ventilation necessary.
13
AREA 
(SQ FT)
Square footage of 
conditioned space
Used to calculate amount of ventilation necessary.
14
VENT 
AIRFLOW
(CFM)
Air delivery rate through 
fresh air duct.
Used to calculate amount of ventilation necessary.
15
Test
Test button
W8150 checks dial and switch settings, activates ventilation for up to three 
minutes and provides feedback to validate if chosen standard can be met.
ON
BEDROOMS
AREA (SQFT)
VENT AIRFLOW (CFM)
REMOTE
A
UX
DAMPER
C
R
G
F
R
C
C
C
C
H
W
G
T
XFMR
1
2
3
4
5
6
7
8
9
13
M19990
14
11
12
10
15
16
17
18
19
20