Honeywell ER150B2006 전단

다운로드
페이지 2
SPECIFICATION DATA
68-3020-2
® U.S. Registered Trademark
Copyright © 2002 Honeywell •  All Rights Reserved 
ER150B2006 and
 ER200B2006 Energy Recovery
 Fresh Air Ventilation Systems
APPLICATION
The ER150 and ER200 Perfect Window™ Fresh Air 
Ventilation Systems provide proper levels of ventilation with 
energy savings by transferring heat and moisture between the 
exhaust and fresh air streams.
FEATURES AND BENEFITS
• Advanced Enthalpic Heat and Moisture Recovery Fixed 
Core. Robust, high performance, reliable design transfers 
heat and moisture between the exhaust and fresh air 
streams, reducing the load on the air conditioner or 
furnace.
• Integral Balancing Dampers:  For quick installation.
• Low Voltage, High-Speed Override. A simple contact 
closure steps up the blower speed to high when high 
demand ventilation is required. Can be connected to the 
Digital Fan Timer or the Energy Recovery Ventilator 
outputs on the Perfect Climate Comfort Center™ (see ven-
tilation data in 68-0171 for hook-up diagrams).
• 4-Speed Fan Control. Multi-level blower provides control 
of the amount of ventilation.
• Automatic Built-in Defrost. Activates automatically to 
prevent the core from freezing.
• Includes Mounting Hardware. Vibration isolation mount-
ing hardware is provided to reduce vibration.
• Insulated Cabinet with Duct Collars. Rugged steel 
cabinet is insulated to reduce blower noise. Duct collars 
provide easy connection of insulated and non-insulated 
duct work.
• Permanent (Washable) Filters. Filters are provided to 
protect the core from contaminants in the air stream. Filters 
are washable.
SPECIFICATIONS
Efficiency Rating:
Sensible Efficiency: 110 cfm at 21°F (16°C) is 79% (perfor-
mance per CAN/CSA-C439-88).
Moisture Transfer Ratio: 
26%.
Air Movement: 
At 0.2 in. wc external static pressure.
ER150B: 150 cfm.
ER200B: 200 cfm.
Install Weight
ER150B: 70 lb (32 kg).
ER200B: 87 lb (40 kg).
Approvals:
Canadian Standards Association: Approved.
ETL: Certified to UL1812.