Installation
MOUNTING THE HOOD TO SUPPORT FRAME
1 Insert four (4) bolts through the top of the hood from the inside.
2  Use four (4) nuts and four (4) washers to secure hood to support frame.
INSTALLING THE ELECTRICAL
1  Remove the wiring box cover.  Remove a knockout from the wiring  
box.
2  Feed 6” of power cable through the knockout opening and secure  
cable to the wiring box with an appropriate connector.
3  Make electrical connections.  Connect white to white, black to black  
and green to green.
4  Replace wiring box cover and screws.  Check that wires are not  
pinched between cover and box.
WASHER
NUT
BOLT
Figure 12
WARNING
Electrical wiring must be done by a qualified person(s) in accordance with all applicable 
codes and standards. This range hood must be properly grounded. Turn off electrical power 
at service entrance before wiring.
WIRING  BOX  COVER
Figure 13