Vermont Casting SDVR 사용자 설명서

다운로드
페이지 44
6
Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters
20007066
9"
(230mm)
Max. Mantel
Width
See 
Fig. 6
6"
(150mm)
Sidewall/
Trim
2
¹⁄₂
"
(63mm)
Rear Wall
9"
(230mm)
Max. Mantel
Width
See 
Fig. 6
6"
(150mm)
Sidewall/
Trim
2
¹⁄₂
"
(63mm)
Rear Wall
Alcove Installation
Fig. 5  Alcove installation.
ST381
PDV20
ST381a
SDVR
Hearth Requirements
The PDV20 and SDVR Heaters must be installed on
rigid flooring. When the heater is installed directly on
any combustible surface other than wood flooring, a
metal or wood panel extending the full width and depth
of the unit must be used as the hearth. There are no
other hearth requirements.
Weight: Fully assembled 350 lbs.
Gas Specifications
Max.
Min.
Input
Input
Model
Fuel
Gas Control
BTU/h
BTU/h
PDV20RN
Nat
Millivolt
21,000
15,500
PDV20RP
Prop
Millivolt
21,000
16,500
PDV20RFN
Nat
Comfort Control
21,000
15,500
PDV20RFP
Prop
Comfort Control
21,000
16,500
SDVRRN
Nat
Millivolt
21,000
15,500
SDVRRP
Prop
Millivolt
21,000
16,500
SDVRRFN
Nat
Comfort Control
21,000
15,500
SDVRRFP
Prop
Comfort Control
21,000
16,500
Natural
LP (Propane)
Inlet Minimum
5.5” w.c.
11.0” w.c.
Inlet Maximum
14.0” w.c.
14.0” w.c.
Manifold Pressure
3.5” w.c.
10” w.c.
Gas Inlet and Manifold Pressures
Mantel Clearances
Combustible
Mantel or Trim
Materials
Noncombustible
Materials
A
B
3" (75mm) Min.
ST382
A = Depth of Mantel and/or Top Trim
B = Height from Top of Heater
PDV20 and SDVR
A (Max.)
B (Min.)
9”
10
¹⁄₂
(230mm)
(270mm)
7
¹⁄₂
9”
(190mm)
(230mm)
6”
7
¹⁄₂
(152mm)
(190mm)
4
¹⁄₂
6”
(114mm)
(152mm)
3”
4
¹⁄₂
(76mm)
(114mm)
1
¹⁄₂
3”
(38mm)
(75mm)
Fig. 6  Mantel / top trim clearances.