TROUBLE SHOOTING  THE GAS CONTROL SYSTEM
SIT 820 NOVA MILLIVOLT VALVE
START
CHECK
GLASS DOOR TO BE REMOVED BEFORE SERVICE WORK
GAS SUPPLY ON
• SHUTOFF VALVE OPEN
•  CONFIRM GAS HOOK-UP
LIGHT PILOT WITH
PIEZO IGNITION
• ELECTRODE GAP MIN. 1/8"
•  ELECTRODE CRACKED
•  ELECTRODE CABLE ATTACHED
•  PIEZO IGNITOR GENERATES
SPARK
•  ELECTRODE CABLE NOT
GROUNDED
PILOT STAYS ON
• FLAME ENGULFING
THERMOCOUPLE BY 3/8"
• THERMOCOUPLE ATTACHED
TO VALVE
• MNIMUM MILLIVOLT:
OPEN CIRCUIT 18MV
CLOSED CIRCUIT 5MV
• VENT SAFETY SWITCH TIGHT
AND NO SHORTS
(FOR UNITS EQUIPPED WITH
VENT SAFETY SWITCH)
MAIN BURNER ON
• REMOTE SYSTEM ON
• REMOTE SYSTEM WIRE
SHORTING OUT
• MINIMUM MILLIVOLT:
OPEN CIRCUIT 300MV
CLOSED CIRCUIT 165MV
• FLAME ENGULFING
THERMOPILE/THERMOCOUPLE
• VALVE IS IN ON POSITION
NO
NO
NO
YES
YES
NO