Kobe Range Hoods CH9630SQB 사용자 설명서

다운로드
페이지 35
 
 
4.  Draw  electrical  wires  through  cabinet 
access opening. 
5. 
From  inside  of  the  hood,  place  screw  (not 
provided)  into  the  exact  center  of  each 
knockout hole and secure to cabinet bottom.  
Once  all  mounting  screws  are  in  place, 
finish  tightening  screws  until  secure.  
CAUTION
:    MAKE  SURE  THE 
HOOD IS SECURE BEFORE RELEASING.
 
6. 
For  safety  purpose,  pre-drilled  mounting 
holes  are  provided  through  the  back  of  the 
hood.  For a more secure installation, use as 
many  mounting  holes  as  needed  to  secure 
from  the  inside  of  hood  (screws  not 
provided).
 
 
Ductwork  Installation 
 
7.  Use  7”  round  steel  pipe  (follow  building 
codes  in  your area)  to  connect  the  exhaust 
on  the  hood  to  the  ductwork  above.    Use 
duct  tape  to  make  all  joints  secure  and  air 
tight.  Refer to Figure 4. 
 
Wiring to Powe r S upply 
 
SAFETY WARNING 
RISK  OF  ELECTRICAL  SHOCK.    THIS 
RANGE 
HOOD 
MUST 
BE 
PROPERLY 
GROUNDED.  MAKE SURE THIS IS DONE BY 
QUALIFIED ELECTRICIAN IN ACCORDANCE 
WITH  ALL  APPLICABLE  NATIONAL  AND 
LOCAL  ELECTRICAL  CODES.    BEFORE 
CONNECTING WIRES, SWITCH POWER OFF 
AT  SERVICE  PANEL  AND  LOCK  SERVICE 
PANEL  TO  PREVENT  POWER  FROM  BEING 
SWITCHED ON ACCIDENTALLY. 
8.  Connect the electrical wires.   
Connect  three  wires  (black,  white  and 
green) to house wires and cap with wire 
connectors.  Connect according to color:  
black to black, white to white, and green 
to green as shown in Figure 5. 
Store wires in the wiring box.  
 
 
 
 
 
 
 
 
 
 
 
Figure 4 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 5 
 
 
 
 
 
 
 
 
 
 
 
Figure 6