Wolf IRG-72 전단

다운로드
페이지 2
NOTE:  In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39067 (04-07)
 MODEL: IRG
INSTANT RECOVERY GRIDDLE
INSTALLATION REQUIREMENTS:
1.  A  gas  pressure  regulator  sized  for  this  unit  is  included.  
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2.  Gas line connecting to appliance must be ¾" diameter or 
larger. If flexible connectors are used, the inside diameter 
must be the same as the ¾" iron pipe.
3.  115  volt,  50/60  Hz,  1  phase  control  circuit.  ½  amp  draw. 
Provided with 6' power cord with 3 prong plug.
4.  An  adequate  ventilation  system  is  required  for  commer-
cial  cooking  equipment.  Information  may  be  obtained  
by  writing  to  the  National  Fire  Protection Association,  
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. 
When writing, refer to NFPA No. 96.
5.  These units are manufactured for installation in accordance 
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est  edition).  Copies  may  be  obtained  from The American 
Gas  Association,  Accredited  Standards  Committee  Z223 
@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.
 
 
NOTE: In the Commonwealth of Massachusetts
 
All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR.
6.  Clearances:
 
 
Combustible 
Non-Combustible
 
Rear 
6" 
0"
 
Sides 
6" 
0"
115 volt, 50/60 Hz, 1 phase control circuit. ½ amp draw. Provided with 6' power cord with 3 prong plug.
 
 
 
 
 
Griddle
 
Model 
 
Griddle 
 
Surface 
Overall 
No. of 
Approx. Ship Wt. (lbs./kg)
 
No. 
BTU/hr. 
Width 
 
Depth 
Width 
Controls 
Counter 
Floor
 
IRG36 
60,000 
36" 
24" 
36" 
475/214 
545/245
 
IRG48 
80,000 
48" 
24" 
48" 
575/259 
665/299
 
IRG60 
100,000 
60" 
24" 
60" 
666/300 
855/385
 
IRG72 
120,000 
72" 
24" 
72" 
855/385 
1080/486