Instructions for the installer
 
 
 
2.3  Room ventilation 
Caution  –  This  cooker  may  only  be  installed  and  operated  in  rooms 
permanently  ventilated  in  accordance  with  current  regulations.  For 
proper operation of a gas appliance it is essential for the air necessary 
 
for combustion of the gas to be able to flow naturally into the room. Air 
 
must  flow  directly  into  the  room  through  openings  in  its  outside  walls. 
This  (these)  opening  (s)  must  have  a  free  passage  cross-section  of  at 
2
least  100  cm ,  or  200  cm
2
  for  appliances  not  equipped  with  gas  safety 
device.  These  openings  must  be  constructed  so  that  they  cannot  be 
obstructed  indoors  or  outdoors,  and  should  preferably  be  close  to  the 
floor on the side opposite to the combustion gas discharge point. If it is 
not  possible  to  make  the  openings  in  the  room  where  the  cooker  is 
installed,  the  necessary  air  may  be  taken  from  an  adjoining  room, 
proveded it is not a bedroom or a room with fire risk. 
 
 
2.4  Clearance above and around domestic cookers 
Extract from AS5601