Raritan Computer DKX2-0E-E 사용자 설명서

다운로드
페이지 257
Network Settings 
 
126
 
 
100 Mbps/Full 
 
1000 Mbps/Full 
Gigabit 
ƒ  Half-duplex provides for communication in both directions, but 
only one direction at a time (not simultaneously). 
ƒ  Full-duplex allows communication in both directions 
simultaneously. 
Note: Occasionally there are problems running at 10 Mbps in either 
half or full duplex. If you are experiencing problems, please try 
another speed and duplex. 
Please refer to Network Speed Settings (on page 195) for more 
information. 
•  Enable Automatic Failover. Check this checkbox to allow Dominion 
KX II to automatically recover its network connection using a second 
network port if the active network port fails. When this option is 
enabled, the following two fields are used: 
ƒ  Ping Interval (seconds). Ping interval determines how often 
Dominion KX II checks the status of the network connection 
(setting this too low may cause excess network traffic). The 
default Ping Interval is 30 seconds. 
ƒ  Timeout (seconds). Timeout determines how long a network port 
must be “dead” before the switch is made. Both network ports 
must be connected to the network and this option must be 
checked for Automatic Failover to function. The default Timeout 
is 60 seconds. 
Note: The default Ping Interval and Timeout generate a condition 
that when the KX device tries to switch over, remote sessions will be 
dropped and must be re-established. Reducing these intervals to 
much lower values will allow remote sessions to stay connected, but 
will result in increased network traffic.