Metrologic Instruments MS7320 사용자 설명서

다운로드
페이지 64
 
 
30 
T
ROUBLESHOOTING 
G
UIDE
 
 
SYMPTOMS POSSIBLE 
CAUSE(S) 
SOLUTION 
Scanning a particular 
symbology that is not 
enabled. 
UPC/EAN, Code 39, interleaved 
2 of 5, Code 93, Code 128 and 
Codabar are enabled by default. 
Verify that the type of bar code 
being read has been selected. 
The unit powers 
up, but does not 
scan and/or 
beep. 
The scanner has been 
configured for a 
character length lock, 
or a minimum length 
and bar code being 
scanned does not 
satisfy the configured 
criteria. 
Verify that the bar code that is 
being scanned falls into the 
criteria.  
(Typical of Non-UPC/EAN 
codes.  The scanner defaults to 
a minimum of 4 character bar 
code.
The unit scans 
a bar code, but 
locks up after 
the first scan 
(red LED stays 
on). 
The scanner is 
configured to support 
some form of host 
handshaking but is not 
receiving the signal. 
If the scanner is setup to support 
ACK/NAK, RTS/CTS, 
XON/XOFF or D/E, verify that 
the host cable and host are 
supporting the handshaking 
properly. 
The unit scans, 
but the data 
transmitted to 
the host is 
incorrect. 
The scanner’s data 
format does not match 
the host system 
requirements. 
Verify that the scanner’s data 
format matches that required by 
the host. Make sure that the 
scanner is connected to the 
proper host port.