Furuno VR-3000S 사용자 설명서

다운로드
페이지 54
 
25
5. INTERFACE 
(IEC 61162-1, IEC 61162-2) 
5.1 Data 
Sentences 
Some sentences described here are the ones proposed by the recent IEC TC80/WG6 (Digital 
Interface Working Group) at the time of this publication. They are marked with PAS 101 or PAS 
102. 
 
ALA - Set detail alarm condition 
        2      3      4      5      6    7    8              9 
$xxALA, hhmmss.ss, aa, aa, xx, xxx, A, A, c—c *hh<CR><LF> 
 
0: Header    1: 
Event time (Optional)    2: System indicator of alarm source 
3: Sub-system/equipment/item indicator of alarm source    4: Number of equipment / units / items 
5: Number of alarm source    6: Alarm condition    7: Alarm’s acknowledge state 
8: Alarm’s description text  9: Check-sum 
 
ALR - Set alarm status      (PAS 101) 
 
Updated the text label of the alarm identification field to be the same as that field in the ACK 
sentence. 
$--ALR,hhmmss.ss,xxx,A,A,c--c*hh<CR><LF> 
 
                          Alarm’s description text 
Alarm’s acknowledge state, A = acknowledged, V= 
unacknowledged 
                Alarm condition (A = threshold exceeded, V = not exceeded) 
            Unique alarm number (identifier) at alarm source 
Time of alarm condition change, UTC