Positioning Your OfficeConnect Hub
When installing your Hub, ensure:
Q
It is out of direct sunlight and away from sources of 
heat.
Q
Cabling is away from power lines, fluorescent lighting 
fixtures, and sources of electrical noise such as radios, 
transmitters and broadband amplifiers.
Q
Water or moisture cannot enter the case of the unit.
Q
Air flow around the unit and through the vents in the 
side of the case is not restricted. We recommend you 
provide a minimum of 25mm (1in.) clearance.
Wall Mounting the OfficeConnect Hub
CAUTION: Only wall mount single units. Do not wall 
mount stacked units.
There are two slots on the underside of the Hub 
which are used for wall mounting. You can mount 
the unit with the LEDs facing upwards or downwards, 
to suit your needs.
When wall mounting the unit, ensure that it is 
within reach of the power outlet.
You need two suitable screws. Ensure that the wall 
you are going to use is smooth, flat, dry and sturdy. 
Make two screw holes which are 142mm (5.6in.) 
apart. Use the guide at the top of this page to mark 
the position of the holes. Fix the screws into the wall, 
leaving their heads 3mm (0.12in.) clear of the wall 
surface.
Remove any connections to the unit and locate it 
over the screw heads. When in line, gently push the 
unit on to the wall and move it downwards to 
secure. When making connections, be careful not to 
push the unit up and off the wall.
Connecting Workstations and Other 
Equipment to Your Hub
WARNING: Ensure you have read the Important 
Safety Information section carefully before you start.
ACHTUNG: Versichern Sie sich, daß Sie den Abschnitt 
mit den wichtigen Sicherheitshinweisen gelesen 
haben, bevor Sie das Gerät benutzen.
AVERTISSEMENT: Assurer que vous avez lu 
soigneusement la section de L’information de 
Sécurité Importante avant que vous commenciez.
CAUTION: The equipment connected to the Hub 
must be set to operate in auto-negotiate or half 
duplex mode.
Connecting workstations and other equipment to 
your Hub is easy. To connect a workstation to any of 
the Hub’s ports, use a ‘straight-through’ TP cable. 
Refer to “Twisted Pair (TP) Cables” on page 3 for 
further information.
If you are using port 8 to connect a workstation, 
ensure the MDI/MDIX switch is set to MDIX (out).
TP cables are very easy to use. To connect a cable, 
simply slot the connector into the appropriate RJ45 
port. When the connector is fully in, its latch locks it 
in place. To disconnect the cable, push the 
connector’s latch in and remove it.
The Hub detects all port connections, so you can start 
using your network immediately. If you need more 
ports, simply add another OfficeConnect hub.