Netgear M4100 사용자 설명서

다운로드
페이지 559
554
   
|    
Chapter 33.  iSCSI 
 
ProSafe M4100 and M7100 Managed Switches 
Set the iSCSI Target Port 
When working with iSCSI that does not use the standard IANA assigned iSCSI ports 
(3260/860), it is recommended that you specify the target IP address. Then the switch will 
only snoop frames where the TCP destination port is one of the configured TCP ports and the 
destination IP is the target IP address. This will improve the performance of the switch by 
preventing the CPU from processing non-iSCSI flows.
The example is shown as CLI commands and as Web interface procedure.
CLI: Set iSCSI Target Port
Use the following commands to set iSCSI target port to 49154 at IP address 172.16.1.20.
(Netgear Switch)  #config
(Netgear Switch)  (Config) #iscsi target port 49154 address 172.16.1.20
(Netgear Switch)  (Config) #exit
Web Interface: Set iSCSI Target Port
1. 
Set iSCI Target Port.
a. a.Select Switching > iSCSI > Advanced > iSCSI Targets
A screen similar to the following displays:
b.  Enter the following information:
•     
In the TCP Port, enter 49154.
•     
In the IP Address, enter 172.16.1.20.
c.  Click Add.