Avaya P550R 사용자 설명서

다운로드
페이지 43
610-0184-095
 18
June 14, 2001
Known Problems and Workarounds
The following known problems and workarounds apply to Cajun 
P550R, P580, P880, and P882 switches that are running switch 
software, v5.2.2. If a known problem has a viable workaround, it 
immediately follows the Problem statement. If the known problem 
has no viable workaround, it is listed as a bulleted statement.
ARP
Problem:  
50-Series and 80-Series modules lose ARPs after you perform an 
initialization of NVRAM (
NVRAM init
).
Workaround:  
Reboot the switch twice after performing an NVRAM init.
ATM Uplink Modules
The following problem has no workaround: 
The 50-series ATM Uplink modules do not work in slot 16 or 
slot 17 if you are using an 80-Series Supervisor module in a 
Cajun P882 switch.
Command Line Interface (CLI)
The following problem has no workaround
The “!” character, when used as part of a CLI command, is 
considered a comment by the Cajun switch software: 
If you type “!” BEFORE a CLI command, the switch 
ignores the command and returns you to the CLI prompt.
If you type “!” after a CLI command, the switch displays 
an Invalid Command or Syntax Error error message.
Flood Rate Limiting
Problem:  
The options for setting flood rate limiting on 80-series, 10/100 
Ethernet modules and on 80-series, 100 Base-FX Ethernet modules 
are incorrect. The correct rates are not available from the Web Agent 
or CLI.