Network Topologies 
 
3.1 Network Topologies 
Ring Topology 
 
 
Figure 3-4 
Ring Topology, Example with SCALANCE X204-2 and SCALANCE X-400 as 
Redundancy Manager 
To increase availability, optical or electrical bus topologies made up of SCALANCE X-200 
switches with a SCALANCE X414-3E, OSM version 2, or ESM version 2 configured as a 
redundancy manager can be closed to form a ring. The SCALANCE X-200 switches are first 
connected over their ring ports to form a bus. The two ends of the bus are closed to form a 
ring by a SCALANCE X414-3E or OSM / ESM operating in the redundancy manager mode. 
In contrast to the ring ports of the SCALANCE X-200 switches, the ring ports of the 
redundancy manager are disconnected from each other during problem-free network 
operation. 
The SCALANCE X414-3E or OSM / ESM operating in the redundancy manager mode 
monitors the connected bus over its ring ports and switches the ring ports through if there is 
an interruption on the connected bus; in other words, it restores a functioning bus over this 
substitute path. Reconfiguration takes place within 0.3 s. 
As soon as the problem has been eliminated, the original topology is restored; in other 
words, the ring ports in the redundancy manager are once again disconnected from each 
other. 