Model EN104/EN108/EN116 Ethernet Hub Installation Guide
The BNC port on the hub, with the BNC T-connector and the 50 
Ω
 terminator, is used for
connecting to a thin coaxial segment.
General Specifications
Network Protocol and Standards Compatibility
IEEE 802.3i, 10BASE-T, 10BASE-2, 10BASE-5 Ethernet 
Data Rate
10 Mbps, Manchester encoded
Interface
10BASE-T ports (RJ-45), BNC port,
AUI port (Model EN108 hub and Model EN116 hub only)
Power Consumption
 
Model EN104 hub
11.0 W
Model EN108 hub
16.5 W
Model EN116 hub
20.5 W
DC Output Voltage (Power Adapter):
Model EN104 hub
1.2 V DC@ 1200 mA max., 47 to 63 Hz
Model EN108 hub
12 V DC @ 1200 mA max., 47 to 63 Hz
Model EN116 hub
12 V DC @ 1200 mA max., 47 to 63 Hz
Physical Specifications
Dimensions:
Model EN104 hub 
3.37 by 4.0 by 1.1 in.
94 by 101 by 28 mm
Model EN108 hub
6.2 by 4.0 by 1.1 in.
158 by 101 by 28 mm
Model EN116 hub
11.3 by 4.0 by 1.1 in.
286 by 101 by 28 mm
Weight:
Model EN104 hub 
0.74 lb (0.34 kg)
Model EN108 hub
1.17 lb (0.53 kg)
Model EN116 hub
1.97 lb (0.89 kg)
Environmental Specifications
Operating temperature:
0
° 
to 40
° 
C (32
° 
to 104
° 
F)
Operating humidity:
90% maximum relative humidity, noncondensing
Electromagnetic Emissions
CE mark, commercial
FCC Part 15 Class A
EN 55 022 (CISPR 22), Class A
VCCI Class 1 ITE
Electromagnetic Susceptibility
CE mark, commercial
Electrostatic discharge (ESD):
IEC 801-2, Level 2/3/4
Radiated electromagnetic field:
IEC 801-3, Level 2
Electrical fast transient/burst:
IEC 801-4, Level 2
Electrical surge:
IEC 801-5, Level 2
Safety Agency Approvals for Power Adapter
CE mark, commercial
UL listed (UL 1950)
CSA certified (CSA 22.2 #950)
TUV licensed (EN 60 950)
T-Mark
8150FA
50
OHM
50 
Ω
 terminator
BNC T-connector
Technical Specifications