Texas Instruments HPL-D SLLU064A 데이터 시트

다운로드
페이지 27
 
EVM WARNINGS AND RESTRICTIONS 
It is important to operate this EVM within the input voltage range of -0.7 V to 4 V and the output voltage range 
of -0.5 V to 4 V. 
Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the 
EVM. If there are questions concerning the input range, please contact a TI field representative prior to 
connecting the input power. 
Applying loads outside of the specified output range may result in unintended operation and/or possible 
permanent damage to the EVM. Please consult the EVM User’s Guide prior to connecting any load to the 
EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. 
During normal operation, some circuit components may have case temperatures greater than 60°C. The 
EVM is designed to operate properly with certain components above 60°C as long as the input and output 
ranges are maintained. These components include but are not limited to linear regulators, switching 
transistors, pass transistors, and current sense resistors. These types of devices can be identified using the 
EVM schematic located in the EVM User’s Guide. When placing measurement probes near these devices 
during operation, please be aware that these devices may be very warm to the touch. 
Mailing Address: 
 
Texas Instruments 
Post Office Box 655303 
Dallas, Texas 75265 
Copyright   2003 - 2004, Texas Instruments Incorporated