5 – Switch Configuration
Installing Firmware
59263-01  A
5-21
A
Non-disruptive Activation
You can load and activate firmware upgrades on an operating switch without 
disrupting data traffic or having to re-initialize attached devices. If the 
non-disruptive activation fails, you will usually be prompted to try again later. 
Otherwise, the switch will perform a disruptive activation. A disruptive activation 
interrupts Fibre Channel data traffic on the switch, while a non-disruptive 
activation does not. For information about non-disruptive firmware versions, see 
the Firmware Release Notes.
To ensure a successful non-disruptive activation, you should first satisfy the 
following conditions:
„
No changes are being made to switches in the fabric including powering up, 
powering down, disconnecting or connecting ISLs, changing switch 
configurations, or installing firmware.
„
No port on the switch is in the diagnostic state.
„
No Zoning Edit sessions are open on the switch.
„
No changes are being made to attached devices including powering up, 
powering down, disconnecting, connecting, and HBA configuration changes.
„
For a fabric in which one or more switches are running firmware prior to 
version 7.4, only one Enterprise Fabric Suite 2007 session can be open.
Install firmware on one switch at a time in the fabric. If you are installing firmware 
on one switch, wait two minutes after the activation is complete before installing 
firmware on a second switch.
Ports that change states during the non-disruptive activation, will be reset. When 
the non-disruptive activation is complete, Enterprise Fabric Suite 2007 and 
QuickTools sessions reconnect automatically. However, Telnet sessions must be 
restarted manually.
                                                                                           
NOTE:
After upgrading firmware that includes changes to QuickTools, a QuickTools 
session that was open during the upgrade may indicate that the new 
firmware is not supported. To correct this, close the QuickTools session and 