Chapter 3: Installation
3-8
2H23-50R/2H33-37R User’s Guide
3.5
CONNECTING TO THE NETWORK
This section provides the procedures for connecting twisted pair and fiber 
optic segments from the network or other devices to the 2H23-50R or 
2H33-37R.
CONN 1 through CONN 4 (2H23-50R) or CONN 1 through CONN 3 
(2H33-37R) each have 12 UTP connections via a 50-pin RJ21 connector. 
If a port is to operate at 100 Mbps, each pair in a cable must be 
Category 5 compliant with an impedance of 85 to 111 ohms.
Slots 5 and 6 of the 2H23-50R support FE-100TX, FE-100FX, or 
FE-100F3 Fast Ethernet Interface Modules.The FE-100TX has an RJ45 
connector for a UTP cable connection. The FE-100FX and FE-100F3 
have SC connectors for fiber optic cable connections.
To make twisted pair connections to CONN 1 through CONN 4 
(2H23-50R) or CONN 1 through CONN 3 (2H33-37R), refer to 
To make a twisted pair connection to an FE-100TX in slot 5 or 6 of a 
2H23-50R, refer to 
.
To make a fiber optic cable connection to an FE-100FX or FE-100F3 in 
slot 5 or 6 of a 2H23-50R, refer to 
.
Refer to the associated High Speed Interface Module user’s guide to make 
connections to an optional High Speed Interface Module installed in the 
HSIM slot of a 2H33-37R.
NOTE
If the device is being installed in a network using 
SmartTrunking, there are rules concerning the cable 
connections and port configurations that must be followed for 
SmartTrunking to operate properly. Before connecting the 
cables, refer to the Cabletron Systems 
SmartTrunk User’s 