Cabletron Systems STHI 사용자 설명서

다운로드
페이지 77
Trouble Resolution
Page 4-2
4.2 Trouble Resolution
If this section does not guide the user to a solution, please contact 
Cabletron Systems Technical Support (see Section 1.4, Getting Help.)
Loss Of Power
1
If the STHI is having power problems, check the power delivery system 
(power cable, power outlet, circuit breaker, fuse).
Failure to Link on Enabled Port
2
Check that the Token Ring devices at either end of the cable are 
powered-up.
Verify that the network cable’s connectors have the proper pinouts. Refer 
to Section 2.2.2, TCU and COM Ports.
Check the cable for continuity. A variety of tools are available for this test, 
depending on the media being used.
Check that the cables meet specifications for dB loss as described in 
Appendix A, TPIM Specifications.
Ring Speed Fault
3
The network device being linked at this port is operating at a ring speed 
different from the STHI hub’s currently set ring speed. Set the two devices 
to the same speed.
Ports 
off
Port enabled but not linked.
Green
Port enabled and linked.
Red
Port disabled (or set to Ring Out) and not linked.
blinking
Red
Ring Speed Fault -OR- Port linked but disabled.
Table 4-1.  LANVIEW LED Signals (Continued)
LED
Color
Condition