Powerware 9395 사용자 설명서

다운로드
페이지 4
225 - 550 kVA
Advanced design delivers 
unequaled power performance
The innovative design of the 
Powerware 9395 delivers the 
industry’s best performance 
combination of efficiency, input 
current distortion and power 
factor. The Powerware 9395 
operates at an industry–leading 
95 percent efficiency, reducing 
utility costs and extending 
battery runtimes. Higher system 
efficiency produces cooler 
operating conditions, which 
reduces facility air conditioning 
cost, extends the life of UPS 
components, and increases 
overall reliability, availability, 
Taking large system mission–
critical reliability to the next step
The Powerware 9395 combines 
the reliability and redundancy 
of a multi-module UPS into an 
integrated, pre-wired solution. 
The Powerware 9395 features 
N+1 redundancy, which 
allows one 275 kVA module to 
automatically carry the load 
in the event the other module 
is out of service. Up to three 
275 kVA modules can be used 
in an integrated solution to 
match the capacity, reliability 
and redundancy needs of your 
application.
Benefits
The Powerware 9395 UPS is designed to meet the current and future power protection 
requirements of data centers, manufacturing operations, medical facilities and other large-
system applications.
  Best total reliability
•  Delivers the highest reliability and availability for large, mission-critical systems by inte-
grating the capabilities of a redundant multi-module UPS (including the System Bypass 
Module) into a single, pre-wired unit
  Unmatched power performance and efficiency
•  Provides unmatched power performance for efficiency, input current harmonic distortion 
(THD), and power factor
  Scalable, redundant architecture meets current and future load requirements
•  Grows with changing power requirements using scalable architecture that allows you to 
add another 275 kVA module on-site later for capacity or redundancy
  Integrates into total PowerChain Management solution from Eaton
•  Integrates seamlessly with Power Xpert
®
 Architecture to enable you to monitor and  
manage the UPS as well as the entire power system, including all upstream and down-
stream switchgear
Incorporating over 40 years of 
technology leadership in the 
design of mission-critical power 
systems, the Powerware 9395 
is an innovative, state-of-the-
art UPS designed to provide 
reliable power to your most 
critical loads. With its capability 
to be configured as a redundant 
system, the Powerware 9395 
is ideal for applications such 
as large data centers, medical 
facilities, or any load that must 
operate 24x7x365 without 
interruption.
Powerware
®
 
9395
Uninterruptible Power System (UPS) 
Product Focus
and performance. A new input 
circuit design keeps input 
current THD low and input 
power factor near unity without 
compromising overall efficiency. 
As a result, the Powerware 
9395 allows maximum transfer 
of power between power 
source and protected load and 
is exceptionally compatible 
with multiple power sources, 
especially auxiliary generators. 
On the output side, the ultra 
high speed switching Pulse 
Width Modulation (PWM) 
inverter enables the Powerware 
9395 to provide its full rated 
power capability to the load 
whether the load power factor is 
0.9 lagging, unity, or 0.9 leading.