4–23
Frequency Arrival Signals
The Frequency Arrival group of outputs help coordinate external systems with the 
current velocity profile of the inverter. As the name implies, output [FA1] turns ON 
when the output frequency arrives at the standard set frequency (parameter F_01). 
Output [FA2] relies on programmable accel/ decel thresholds for increased flexibility. 
For example, you can have an output turn ON at one frequency during acceleration, and 
have it turn OFF at a different frequency during deceleration. All transitions have hyster-
esis to avoid output chatter if the output frequency is near one of the thresholds.
Option
Code
Terminal 
Symbol
Function Name
Output 
State
Description
01
FA1
Frequency Arrival 
Type 1 – Constant 
Speed
ON
when output to motor is at the set frequency
OFF
when output to motor is OFF, or in any accelera-
tion or deceleration ramp
02
FA2
Frequency Arrival 
Type 2 – Over-
frequency
ON
when output to motor is at or above the set 
frequency thresholds for, even if in acceleration 
or deceleration ramps
OFF
when output to motor is OFF, or during accelera-
tion or deceleration before the respective thresh-
olds are crossed
Valid for outputs:
11, 12
Required settings:
(none)
Notes:
For most applications you will need to use only one 
type of frequency arrival outputs (see examples). 
However, it is possible assign both output terminals 
to output functions [FA1] and [FA2].
For each frequency arrival threshold, the output 
anticipates the threshold (turns ON early) by 1.5Hz.
The output turns OFF as the output frequency 
moves away from the threshold, delayed by 0.5Hz.
The delay time of the output signal is 60 ms 
(nominal).