IGBT Test Method
The following procedure will check the inverter transistors (IGBTs) and diodes:
1. Disconnect input power to terminals [R, S, and T] and motor terminals [U, V, and W].
2. Disconnect any wires from terminals [+] and [–] for regenerative braking.
3. Use a Digital Volt Meter (DVM) and set it for 1
Ω resistance range. You can check the 
status of the charging state of terminals [R, S, T, U, V, W, +, and –] of the inverter and 
the probe of the DVM by measuring the charging state.
Table Legend – Almost infinite resistance: 
≅  ∞ Ω   Almost zero resistance: ≅ 0 Ω
NOTE: The resistance values for the diodes or the transistors will not be exactly the 
same, but they will be close. If you find a significance difference, a problem may exist.
NOTE: Before measuring the voltage between [+] and [–] with the DC current range, 
confirm that the smoothing capacitor is discharged fully, then execute the tests.
Part
DVM
Measured
Value
Part
DVM
Measured
Value
Part
DVM
Measured
Value
+
+
+
D1
[R]
+1
≅ ∞ Ω
D5
[S]
[N]
≅ 0 Ω
TR4
[U]
[–]
≅ 0 Ω
+1
[R]
≅ 0 Ω
[N]
[S]
≅ ∞ Ω
[–]
[U]
≅ ∞ Ω
D2
[S]
+1
≅ ∞ Ω
D6
[T]
[N]
≅ 0 Ω
TR5
[V]
[–]
≅ 0 Ω
+1
[S]
≅ 0 Ω
[N]
[T]
≅ ∞ Ω
[–]
[V]
≅ ∞ Ω
D3
[T]
+1
≅ ∞ Ω
TR1
[U]
[+]
≅ ∞ Ω
TR6
[W]
[–]
≅ 0 Ω
+1
[T]
≅ 0 Ω
[+]
[U]
≅ 0 Ω
[–]
[W]
≅ ∞ Ω
D4
[R]
[N]
≅ 0 Ω
TR2
[V]
[+]
≅ ∞ Ω
TR7
[RB]
[+]
≅ 0 Ω
[N]
[R]
≅ ∞ Ω
[+]
[V]
≅ 0 Ω
[+]
[RB]
≅ ∞ Ω
TR3
[W]
[+]
≅ ∞ Ω
[RB]
[–]
≅ 0 Ω
[+]
[W]
≅ 0 Ω
[–]
[RB]
≅ 0 Ω
[R]
[S]
[T]
TR1
TR2
TR3
[U]
[V]
[W]
[–]
D1
D2
D3
D4
D5
D6
+
[+]
[+1]
TR4
TR5
TR6