  Selects five different maintenance functions.
Test Print
 
  Each test print function is activated by pressing the Ø
key.
   Current Config
 
  Prints labels reflecting the printer’s current settings.
   Database Config
 
  Prints labels reflecting the menu settings.
   Test Ribbon
 
  Prints a series of Ribbon Test Labels.
   Test Pattern
 
  Printhead dot pattern test label.
Front Panel
 
  Tests three different Front Panel functions.
    LED Test
 
  Toggles the Ribbon/Paper and Pause LED’s on the
control panel.
   Keypad Test
 
  Allows user testing of the six-button menu control
pad. The display will indicate the functions of the
keys as they are pressed.  Pressing twice on the ×
will exit the test.
   Display Test
 
  Cycles alphanumeric characters through each
segment of the LCD display.
Test I/O
 
  Tests three different I/O functions.
   Monitor GP Input
 
  Active monitor of the General Purpose I/O inputs.
   Test GP Output
 
  Tests the General Purpose I/O outputs.
   Sensor Readings:
 
  Divided into two sections.
      Digital
 
  Indicates the conditions of the printer’s digital
sensors.  The top line contains the sensor input,
while the bottom line shows the sensor state.  See
Table 4-1 for definitions.
      Analog
 
  Indicates the converted values of four analog
sensors. The top line contains the sensor input, while
the bottom line shows a digital representation of the
analog value.  See Table 4-1 for definitions.
Serial Loopback
 
  Serial Loopback tests the internal transmit, receive
and CTS/DTR signals.  A special loopback plug
must be installed on the port under test (see Figure 4-
1).  When complete, the printer will respond with the
results.
   Serial Port A
 
  Tests Port A.
   Serial Port B
 
  Tests Port B.