Citizen Systems iDP-3535 사용자 설명서

다운로드
페이지 38
iDP-3535 User’s Manual
 CITIZEN
29/38
Usage of the DIP switch
Type
Preset JP. Line
Dig SW.
Paper
Cash
Connector
Command
JP 1
JP 2
JP 3
DIP 1-6
Winder
Drawer
(PIN)
Code (HEX)
E type
ON
OFF
ON
ON
L1(AW-3)
-
CN 3-2
LF (0A)
-
L2
CN 6-2.5
SUB (1A)
OFF
-
L1
CN 3-2
BELL (07)
-
L2
CN 6-2.5
SUB (1A)
U-type
ON
ON
OFF
ON
L1(AW-3)
-
CN 3-2*1
LF (0A)
CN 6-2
-
L2
CN 6-5
SUB (1A)
OFF
L1
CN 3-2*1
BELL (07)
-
CN 6-2
-
L2
CN 6-5
SUB (1A)
*1. Do not connect External Device L1 (Drawer and Winder) to the connectors CN3-2 and CN6-2
at the same time.
Note : 
1) External device 1 and 2 can not be driven at the same time. In case the device is driven continuously,
  the duty note should be less than 20%.
2) The resistance of L1, L2 should be more than 36 
Ω
.