ISSUED: 03-06-08  SHEET #: 154-9009-2 07-10-08
5 of 6
Visit  the  Peerless  Web  Site  at  www.peerlessmounts.com
For Technical Support Contact Peerless Mounts at 1-800-729-0307 or 708-865-8870.
Adjustment of Extension Column
• Extension column (A) must be fully threaded (six or seven full turns) onto threaded fitting in ceiling plate and then
locked with M5 x 10 mm screw.
WARNING
2
fig. 2.2
fig. 2.3
Skip to step 3 if adjustment is not required.
Remove M8 x 10 mm phillips screw from set hole in extension column (A) as shown in fig. 2.1. Slightly loosen
M8 x 10 mm phillips screw in hook slot until inner column is loose. Rotate inner column left and slide down in to
desired hook slot as shown in fig. 2.2 and 2.3. Securely tighten M8 x 10 mm phillips screw in hook slot. Fasten
M8 x 10 mm phillips screw into set hole and inner column and retighten M8 x 10 mm phillips screw in hook slot as
shown in fig. 2.1.
INNER COLUMN
HOOK SLOT
M8 x 10 MM
PHILLIPS SCREW
M8 x 10 MM
PHILLIPS SCREW
• Do not loosen M8 x 10 mm screw to point of
disengagement. Hold inner column securely while
adjusting M8 x 10 mm screw. Tighten fasteners
securely.
WARNING
fig. 2.1
A
INNER COLUMN
M8 x 10 MM
PHILLIPS SCREW
SET HOLE