Power Up 
Sequence
When the Vanguard 342 power cord is plugged into the power supply outlet, you will 
see the following power up sequence:
 
Detailed FT1/FE1 
LED 
The FT1/FE1 daughtercards have one LED located on the rear panel. Software 
controls the LED and indicates the following when ON or OFF:
• ON - Alarm condition data path is disrupted, refer to the FT1/FE1 interface 
statistics for more information on the problem.
• OFF - Normal operation exists.
Stage
when...
...this indicates 
1
Power (PWR) LED turns on 
(GREEN)
Vanguard is receiving power.
2
PWR LED remains on and the 
Status (STAT) LED blinks 
(RED).
Diagnostics are starting.
3
PWR LED blinks.
Diagnostics are executed.
4
PWR LED remains on and the 
STAT LED blinks.
Indicates software is being 
downloaded from FLASH.
5
PWR LED blinks.
Software is initializing your system 
configuration.
6
PWR LED remains on.
Your system is running.