he M-27 may draw additional current when connected to a printer. For best results connect the M-
27 to a printer only when printing data. 
 
INTERNAL SWITCHES 
 
The M-27 is set at the factory to the current OSHA requirements unless otherwise specified. When 
the CODE key is pressed, the display shows a coded display of the current internal switch settings. As an 
example, if the display is a 4-digit display such as 10EE, then the unit is set to a criterion level of 90 dB for 
8 hours, an exchange rate of 5 dB, a high threshold level of 90 dB, a low threshold level of 80 dB, 115 dB 
upper limit level, "A" frequency weighting, the 50 dB to 146 dB range, a SLOW time constant and a 12-
hour clock. 
 
If the display is a 3-digit code then the first number is the unit identification number. The next two 
digits are the printer setup. The printer setup may be changed at any time without erasing data. The other 
switches are only read when the unit is reset. 
 
Some examples of common switch settings and codes are as follows:
 
OSHA Compliance and Hearing Conservation 
 
"A" Weighting               90 dB High                   Parallel Printer
 
50-146 dB Range          Threshold                      Text and Graph
 
115 dB Upper Limit      80 dB Low Threshold    LF and CR
 
Slow Time Constant     12 Hour Clock                600 Baud
 
90 dB Criterion             Unit Unit #1  